Back to Search

AAIB investigation to Evolve Dynamics Sky Mantis, UAS, registration n/a

Air Accidents (AAIB)

Published on 11 July 2019, 10:22

Summary
Loss of power, Nailsea Fire Station, Somerset, 7 February 2019.
aircraft category
unmanned-aircraft-systems
aircraft type
Evolve Dynamics Sky Mantis
date of occurrence
2019-02-07
location
Nailsea Fire Station, Somerset
registration
UAS registration n/a
report type
correspondence-investigation

Report Overview

Summary:

During a demonstration flight, the UAS dropped to the ground from a height of 50 m when the electric motors stopped, despite the battery being fully charged. The UAS struck the ground and was destroyed in the subsequent post-impact fire. The UAS manufacturer determined that the loss of power was caused by the battery not being fully locked in place. It has updated the operations manual and intends to install sensors to prevent the aircraft from operating if the battery is not correctly locked in place.

This overview has been truncated. Please refer to the official documents below for the complete canonical report.

Official Documents

Document Content Preview

Extracted text from the first few pages of the official documents.

Evolve Dynamics Sky Mantis, UAS 07-19

75� Crown copyright 2019 All times are UTC AAIB Bulletin: 7/2019 Sky Mantis EW/G2019/02/06 ACCIDENT Aircraft Type and Registration: Evolve Dynamics Sky Mantis (UAS, registration n/a) No & Type of Engines: 4 electric motors Year of Manufacture: 2019 (Serial no: ED/SM68-00212) Date & Time (UTC): 7 February 2019 at 1022 hrs Location: Nailsea Fire Station, Somerset Type of Flight: Commercial Operations Persons on Board: Crew - N/A Passengers - N/A Injuries: Crew - N/A Passengers - N/A Nature of Damage: Aircraft destroyed Commander’s Licence: Other Commander’s Age: 27 years Commander’s Flying Experience: 7 hours (of which 4 were on type) Last 90 days - 5 hours Last 28 days - 2 hours Information Source: Aircraft Accident Report Form submitted by the pilot and subseqeunt AAIB enquires Synopsis During a demonstration flight, the UAS dropped to the ground from a height of 50 m when the electric motors stopped, despite the battery being fully charged. The UAS struck the ground and was destroyed in the subsequent post-impact fire. The UAS manufacturer determined that the loss of power was caused by the battery not being fully locked in place. It has updated the operations manual and intends to install sensors to prevent the aircraft from operating if the battery is not correctly locked in place. History of the flight The Evolve Dynamics Sky Mantis is an all-weather long endurance quadcopter UAS, which is still under development. It has a maximum takeoff mass of 6.9 kg and a 60-minute endurance (Figure 1). The pilot, who works for the UAS manufacturer, was operating the UAS on a demonstration flight. It was the first flight of the day and prior to taking off, the battery level indication had indicated a 100 % state of charge and a voltage of 25.2 V. The UAS took off at maximum takeoff mass and indicating an available flight time of 60 minutes. The pilot climbed the UAS to a height of 50 m where it maintained a stable hover. It had been flying for approximately 5 minutes when the pilot initiated a control input to rotate the UAS about its yaw axis. Whilst yawing, the UAS appeared to suffer a complete power failure; all four electric motors stopped and the UAS began descending rapidly. There were no associated warnings 76� Crown copyright 2019 All times are UTC AAIB Bulletin: 7/2019 Sky Mantis EW/G2019/02/06 displayed on the controller and the UAS did not respond to any control inputs by the pilot. It entered autorotation at approximately 10 - 15 m above the ground, but this was insufficient to arrest the rate of descent and it struck the ground hard. The onboard battery ignited and the UAS was destroyed in the ensuing fire. Figure 1 Evolve Dynamics Sky Mantis Investigation by the UAS manufacturer The UAS manufacturer undertook an internal investigation to determine the cause of the power loss. It identified that the battery had not been fully locked in place during the accident flight and vibration had caused it to lose contact with the electrical connections, leading to the loss of power. Safety action The manufacturer has since updated the Sky Mantis Operations Manual to include an instruction to check that the battery is locked in place and will include this requirement in customer training. It also intends to install sensors in the battery lock mechanism which will prevent the aircraft from being able to fly if the battery is not correctly locked in place.

Change History

  • First published.