Back to Search

Boeing 737-377, G-CELS, 1 March 2013

Air Accidents (AAIB)

Published on 10 December 2014, 22:52

Summary
aircraft category
commercial-fixed-wing
aircraft type
Boeing 737-377
bulk published
1
date of occurrence
2013-03-01
location
Stand 25, London Gatwick Airport
registration
G-CELS
report type
field-investigation

Report Overview

Boeing 737-377, G-CELS

Summary:

During pre-flight preparations smoke was seen coming from the overhead bin over seat row 1 D, E, F. The smoke was caused by arcing across the pins of the redundant No 2 Galley electrical connector. Tests confirmed that the connector remained powered despite the No 2 Galley CB being pulled and collared. A previous inspection had identified this issue, but the operator’s maintenance systems allowed the task to be closed prior to completion of the rectification work. The operator has changed the systems used to control such inspections to ensure that additional work must be completed before the inspection is closed. Any aircraft which may have been similarly affected, have been reinspected.

This overview has been truncated. Please refer to the official documents below for the complete canonical report.

Official Documents

Document Content Preview

Extracted text from the first few pages of the official documents.

Boeing 737-377, G-CELS 12-13.pdf

13� Crown copyright 2013 AAIB Bulletin: 12/2013 AAIB Bulletin: 12/2013 G-CELS EW/C2013/03/01 INCIDENT Aircraft Type and Registration: Boeing 737-377, G-CELS No & Type of Engines: 2 CFM56-3B2 turbofan engines Year of Manufacture: 1986 (Serial no: 23660) Date & Time (UTC): 1 March 2013 at 0912 hrs Location: Stand 25, London Gatwick Airport Type of Flight: Commercial Air Transport (Passenger) Persons on Board: Crew - 6 Passengers - None Injuries: Crew - None Passengers - N/A Nature of Damage: Minimal damage around electrical connector Commander’s Licence: Airline Transport Pilot’s Licence Commander’s Age: 49 years Commander’s Flying Experience: 11,701 hours (of which 3,015 were on type) Last 90 days - 98 hours Last 28 days - 15 hours Information Source: Aircraft Accident Report Form submitted by the pilot Synopsis During pre-flight preparations smoke was seen coming from the overhead bin over seat row 1 D,  E, F. The smoke was caused by arcing across the pins of the redundant No 2 Galley electrical connector. Tests confirmed that the connector remained powered despite the No 2 Galley CB being pulled and collared. A previous inspection had identified this issue, but the operator’s maintenance systems allowed the task to be closed prior to completion of the rectification work. The operator has changed the systems used to control such inspections to ensure that additional work must be completed before the inspection is closed. Any aircraft which may have been similarly affected, have been reinspected. History of the flight The aircraft was being prepared for a ferry flight by the crew when electrical ground power was lost. After checking the power supply, electrical power was restored and the crew continued with their preparations. Shortly afterwards the Senior Cabin Crew Member reported smoke and sparks coming from the vicinity of the overhead locker above seat row 1 D,E, F. After ordering the cabin crew to leave the aircraft, the flight crew carried out the QRH drills and declared a MAYDAY before leaving the aircraft. The AFRS attended the aircraft and confirmed that smoke and sparks had originated from an electrical connector which was positioned close to damp sound insulation material. 14� Crown copyright 2013 AAIB Bulletin: 12/2013 AAIB Bulletin: 12/2013 G-CELS EW/C2013/03/01 Investigation An investigation carried out by the operator’s engineering organisation determined that the smoke and sparks had been caused by arcing across the pins of an electrical connector previously used to provide power to the No 2 galley unit, which had been removed from the aircraft. Tests confirmed that, despite the CB for the galley unit being tripped and collared, voltage was still present at the connector pins. The connector was removed from the aircraft and the wires capped and stowed. In 2012 a Line Maintenance Work Request (LMWR) had been raised to inspect the operator’s fleet, including G-CELS, after a similar event identified the possibility of the redundant galley connector remaining powered despite the No 2 Galley CB being tripped. Analysis of the results of this LMWR showed that in the case of G-CELS, and a number of other aircraft, the LMWR had identified that the connector remained live but the system for controlling the LMWRs allowed them to be closed without confirmation that additional work identified had been completed. Safety action The operator carried out an additional inspection of those aircraft which the results of the previous LMWR indicated may have required additional work. One other aircraft was found to have a live No 2 Galley connector. The operator has reviewed its procedure for the management of LMWRs and introduced new systems and procedures which will ensure that any additional work identified as a result of carrying out an LMWR is completed before the LMWR can be closed.

Change History

  • First published.

Related Entities

Search the database for other reports involving these entities.