Back to Search

Boeing 737-436, G-DOCE, 30 May 2003

Air Accidents (AAIB)

Published on 10 December 2014, 20:52

Summary
aircraft category
commercial-fixed-wing
aircraft type
BOEING 737-436
bulk published
1
date of occurrence
2003-05-30
location
In flight near Lyon, France
registration
G-DOCE
report type
field-investigation

Report Overview

Boeing 737-436, G-DOCE

Download report:

dft-avsafety-pdf-029046.pdfDownload (143.93 kb)

This overview has been truncated. Please refer to the official documents below for the complete canonical report.

Official Documents

Document Content Preview

Extracted text from the first few pages of the official documents.

dft-avsafety-pdf-029046.pdf

1 Boeing 737-436, G-DOCE AAIB Bulletin No: 6/2004 Ref: EW/C2003/05/06 Category: 1.1 INCIDENT Aircraft Type and Registration: Boeing 737-436, G-DOCE No & Type of Engines: 2 CFM56-3C1 turbofan engines Year of Manufacture: 1991 Date & Time (UTC): 30 May 2003 at 1630 hrs Location: In flight near Lyon, France Type of Flight: Public Transport (Passenger) Persons on Board: Crew - 6 Passengers - 128 Injuries: Crew - None Passengers - 7 (Minor) Nature of Damage: Burnt wiring loom Commander's Licence Air Transport Pilots licence Commander's Age: 34 years Commander's Flying Experience: 8,000 hours (of which 1,500 were on type) Last 90 days - 100 hours Last 28 days - 40 hours Information Source: AAIB Field Investigation Synopsis Whilst in the cruise the crew began to feel some discomfort in their ears. This was shortly followed by the cabin altitude warning horn which indicated that the cabin altitude had exceeded 10,000 feet and this was seen to continue to climb on the cockpit gauge. At the same time, the primary AUTO mode of the pressure control failed, shortly followed by the secondary STBY mode. The crew selected the first manual pressure control mode, but were unable to control the cabin altitude. An emergency descent and subsequent diversion to Lyon was carried out. The failure of the pressurisation control system was traced to burnt electrical wiring in the area aft of the aft cargo hold. The wiring loom had been damaged by abrasion with either a p-clip or 'zip' strap that, over time, resulted in the conductors becoming exposed, leading to short circuits and subsequent burning of the wires. There was no other damage. The wiring for all the modes of operation of the rear outflow valve, in addition to other services, run through this loom. History of flight G-DOCE was being operated from Marseille, France, to London Gatwick Airport (LGW). The initial stages of the flight had been without incident but a few minutes into the cruise, when at FL340, the crew felt discomfort in their ears, followed by the sounding of the cabin altitude warning horn. The crew checked the overhead pressurisation control panel (PCP) and confirmed that the cabin altitude Boeing 737-436, G-DOCE 2 was indeed climbing. At this stage the pressurisation primary AUTO control system failed, which was indicated to the crew by the illumination of the AUTOFAIL light, and the system automatically switched to its first back up system (STBY). The STBY light illuminated to indicate this but a few seconds later, the light extinguished, indicating that all automatic pressurisation control systems had now failed. The crew then selected the first manual control system, MAN AC. Despite operating the toggle switch, which directly controls the rear outflow valve (OFV), the position indication in the cockpit showed that it was fully closed with no apparent response to the control inputs. As a result, the crew put on their oxygen masks and initiated an emergency descent at 6,000 fpm to quickly attain an aircraft altitude below 10,000 feet. The aircraft then diverted to Lyon, France. On arrival at Lyon several passengers were treated with ear and sinus problems as a result of the depressurisation. An investigation by the operator into the cause of the failure was initiated at Lyon. No circuit breakers (CBs) were found tripped and the OFV was operable in both the STANDBY and the MAN DC modes, although the OFV position indication to the cockpit was faulty. It was confirmed that the valve could not be operated in either AUTO or MAN AC. The aircraft was ferried back to LGW in an unpressurised state with all the pressure control system CBs tripped and the OFV in the open position. After the flight to LGW, entries were made in the aircraft's technical log stating that the aft drain mast heater CB had tripped in flight and that when the CB was reset, it tripped again immediately. Pressurisation System The Boeing 737-400 cabin pressure control system is used to control the air outflow from the pressurised section of the fuselage, in flight, so that the cabin altitude is kept at a level suitable for the passengers and crew. Also, the difference between the pressure in the cabin and the ambient air is kept below a specified limit for structural considerations. This is achieved mainly by the use of the rear OFV, which bleeds air from the cabin in a controlled manner, and provides a balance between the inflow of air from the air conditioning system and the air outflow. (Additionally, a forward OFV is installed, but this is either in the open or closed position and is not modulated by the pressure control system.) To achieve this, the rear OFV is fitted with two motors, one DC powered, the other AC powered. In normal operation the single pressure controller operates in AUTO mode, which controls the OFV AC motor on the OFV with the positional feedback signal derived from a potentiometer. If the AUTO mode senses a problem, such as the cabin altitude rising in excess of 1,900 sea level feet per minute (slfpm) the controller automatically changes over to the back-up STBY mode, and this is indicated to the flight crew by AUTOFAIL and STBY lights on the PCP. In STBY mode, the pressure controller still automatically controls the OFV, but now uses the back-up DC motor to modulate the valve. Control of the cabin pressurisation is then based on inputs of differential pressure and cabin rates of climb/descent which the crew provide via the PCP. If the STBY mode should then fail, indicated by the STBY light extinguishing, there are still two back up manual modes of operation. In these modes the crew have direct control of the OFV position, via a toggle switch on the PCP, with reference to the OFV position indicator, cabin pressure gauge and differential pressure gauge. Manual control is either via the AC motor (AC MAN), previously used by the AUTO mode, or the DC motor (DC MAN) previously used in the STBY mode. OFV position feedback is signalled from the same potentiometer as when the system is operated under automatic control. If the cabin altitude exceeds 10,000, feet a warning is given to the crew but if the cabin altitude continues to climb to over 14,000 feet, oxygen masks in the passenger cabin will automatically deploy. Quick Access Recorder Data G-DOCE was equipped with a quick access data recorder which, amongst the recorded parameters, was a signal derived directly from a cabin pressure sensor. This data showed that the cabin altitude had stabilised during the climb at approximately 7,000 feet and, some 43 seconds after the aircraft had Boeing 737-436, G-DOCE 3 reached its cruise level of FL340, that the cabin altitude began to climb rapidly. Within seven seconds this had reached an altitude in excess of 10,000 feet and the cabin altitude warning was signalled at this point. The cabin altitude continued to climb and reached a maximum of approximately 11,000 feet. As the aircraft made an emergency descent, at about 6,000 fpm, the cabin altitude also began to descend, indicating that there was a measure of control over the cabin pressure. The aircraft eventually levelled off at 7,000 feet with a cabin altitude around -1,000 feet. Engineering Investigation After the aircraft's arrival at LGW, the OFV was replaced. Whilst this was being carried out it was noticed that the over-pressure relief valve, on the left hand side of the airframe, had insulation blanket material trapped inside its mechanism, indicating that it had operated to prevent an excessive pressure in the fuselage at some point in the past. This valve was also replaced and a check for damage, following an over pressurisation event, was also carried out. No damage was found, except for a blow-out panel, which had dropped down in the aft cargo hold. The replacement of the OFV failed to rectify the problem, and so the next course of action was to replace the pressure controller. The

Change History

  • First published.

Related Entities

Search the database for other reports involving these entities.